Free practice test
Practice for the EPA Section 608 technician exam, section by section. Pick an answer to see whether it is right and the rule behind it, with the section of the federal regulation it comes from.
Federal law requires EPA 608 certification to open a refrigerant circuit, so HVAC and refrigeration employers ask for it before you start.
Pick an answer to see whether it is right. Each explanation shows why, with the rule or the working behind it, so a wrong answer still teaches you something.
Core (24) · Type I: small appliances (25) · Type II: high-pressure and very high-pressure appliances (25) · Type III: low-pressure appliances (25)
Ozone science, the Clean Air Act and Montreal Protocol, the Section 608 rules that apply to every technician, refrigerant handling and safety.
1. Under 40 CFR 82.154(a), which refrigerant is exempt from the venting prohibition in any application?
C. Carbon dioxide. Carbon dioxide, nitrogen and water are exempt from the venting prohibition in any application. R-410A and R-134a are non-exempt HFC substitutes and R-22 is an HCFC, so none of them may be knowingly vented.
From 40 CFR 82.154(a)(1)
2. Which of these refrigerant releases is permitted under the Section 608 venting prohibition?
A. A de minimis release when hoses are connected or disconnected during a good-faith recovery. Only de minimis releases made during good-faith attempts to recover or recycle (such as when connecting or disconnecting hoses), releases during normal operation, and releases of exempt substitutes are allowed. Venting during service or disposal is prohibited.
From EPA, Prohibition on Venting Refrigerants (Types of Releases); 40 CFR 82.154(a)(2)
3. Ranked from highest ozone depletion potential (ODP) to lowest, which order is correct?
B. CFCs, HCFCs, HFCs. CFCs have the highest ODP. HCFCs also contain chlorine but have much lower ODPs (about 0.01 to 0.1). HFCs contain no chlorine, so their ODP is zero.
From EPA, Section 608 Test Topics: Core, Environmental Impacts
4. R-22 belongs to which class of refrigerant?
D. HCFC. R-22 is a hydrochlorofluorocarbon (HCFC). R-12 is a CFC and R-134a is an HFC.
From EPA, Section 608 Test Topics: Core, Environmental Impacts
5. Which atom, released when CFCs and HCFCs break down in the stratosphere, destroys ozone (one atom can destroy over 100,000 ozone molecules)?
B. Chlorine. Strong UV light in the stratosphere breaks CFCs and HCFCs apart and frees chlorine. One chlorine atom can destroy over 100,000 ozone molecules before it is removed from the stratosphere.
From EPA, Basic Ozone Layer Science, II. Ozone Depletion
6. Ozone depletion lets more UVB radiation reach the ground. Which human health effects does EPA link to more UVB?
D. Skin cancer and cataracts. UVB causes non-melanoma skin cancer, plays a major role in melanoma, and has been linked to cataracts. A thinner ozone layer lets more of it reach the surface.
From EPA, Health and Environmental Effects of Ozone Layer Depletion: Effects on Human Health
7. Ozone depletion potential (ODP) compares a substance's effect on ozone with the same mass of which reference substance, whose ODP is 1.0?
D. CFC-11. ODP is measured against CFC-11, defined as 1.0. Carbon dioxide is the reference for global warming potential (GWP), not ODP.
From EPA, Ozone-Depleting Substances (ODP and GWP definitions)
8. U.S. production and import of CFCs (other than exempted uses) ended on January 1 of which year?
C. 1996. The ban on production and import of Class I substances such as CFCs took effect January 1, 1996. Halons were banned earlier, on January 1, 1994.
From EPA, Phaseout of Class I Ozone-Depleting Substances
9. Since January 1, 2020, what is the status of HCFC-22 (R-22) production and import in the United States?
B. No production or import is allowed. Since 2020 no HCFC-22 may be produced or imported. Existing R-22 equipment can still be serviced with R-22 already in supply, such as reclaimed R-22. The 2030 date is the end for all remaining HCFCs.
From EPA, Phaseout of Class II Ozone-Depleting Substances (phaseout schedule table)
10. What is the Montreal Protocol?
A. The international treaty that phases out production of ozone-depleting substances. The Montreal Protocol is the international agreement to phase out production of ozone-depleting substances. The certification program comes from the Clean Air Act, and the reclaim purity standard is AHRI Standard 700.
From EPA, Section 608 Test Topics: Core, Clean Air Act and Montreal Protocol
11. A technician holds only Section 609 (motor vehicle air conditioning) certification. Can he buy a 25-pound cylinder of R-410A for a residential split system?
D. No, only Section 608 certified technicians may buy refrigerant for stationary equipment. Section 609 certified technicians can buy only refrigerant acceptable for motor vehicle air conditioners. Refrigerant intended for stationary equipment may be sold only to Section 608 certified technicians (or employers of one), whatever the container size.
From EPA, Refrigerant Sales Restriction: Requirements to Purchase Refrigerant
12. Which refrigerant purchase does NOT require the buyer to be certified?
B. An R-134a can for a car that holds 2 pounds or less and has a unique fitting and a self-sealing valve. The sales restriction covers CFCs, HCFCs and non-exempt substitutes such as HFCs. The one exception for substitutes is motor vehicle refrigerant in containers of 2 pounds or less with a unique fitting and, if made on or after January 1, 2018, a self-sealing valve.
From 40 CFR 82.154(c)(1)(ix)
13. Without being recycled or reclaimed, recovered refrigerant may be charged back into which appliance?
C. The appliance it came from, or another appliance owned by the same person. Recovered refrigerant may go back into the appliance it was taken from or another appliance owned by the same person (except motor vehicle and MVAC-like systems). If it changes owners, it must be reclaimed first.
From 40 CFR 82.156(h)
14. R-410A recovered from one customer's system is to be sold to a different owner. What must happen first?
A. It must be reclaimed by an EPA-certified reclaimer to the AHRI Standard 700 specifications. Used refrigerant may not be sold to a new owner unless it has been reclaimed by an EPA-certified reclaimer, which means reprocessing it to the Appendix A (AHRI 700-2016) specifications and verifying each batch by analysis.
From 40 CFR 82.154(d) and 82.164(a)
15. Which activity makes a person a technician who must be certified?
D. Attaching and detaching hoses and gauges to the appliance. Attaching or detaching hoses and gauges, adding or removing refrigerant, adding or removing components and cutting refrigerant lines can break the integrity of the refrigerant circuit, so they need certification. Painting, external rewiring, replacing pipe insulation and tightening nuts and bolts do not.
From 40 CFR 82.152, definition of Technician
16. A registered apprentice who is not yet certified wants to recover refrigerant from a rooftop unit. When is this allowed?
B. When the apprentice is closely and continually supervised by a certified technician. Apprentices registered with the U.S. Department of Labor's Office of Apprenticeship (or a recognized State Apprenticeship Council) are exempt from certification while closely and continually supervised by a certified technician. A person can be an apprentice for only two years from first registering.
From 40 CFR 82.161(a)(2) and 82.152, definition of Apprentice
17. How long is a Section 608 technician certification valid?
C. It does not expire. Section 608 certification credentials do not expire. EPA keeps the right to require recertification in the future by notice in the Federal Register, but has not done so.
From EPA, Section 608 Technician Certification Requirements; 40 CFR 82.161(a)(5)
18. Which gas should be used to pressurize a system for leak testing?
A. Dry nitrogen. Use nitrogen, never oxygen or compressed air, to pressurize a system for leak testing, and always use it with a pressure regulator and a relief valve.
From EPA, Section 608 Test Topics: Core, Safety
19. What is the most a refrigerant recovery cylinder should be filled?
C. 80 percent. A recovery cylinder should never be filled more than 80 percent full. The space left allows the liquid to expand as it warms; a cylinder filled further risks becoming liquid-full and bursting.
From EPA, Section 608 Test Topics: Core, Safety (filling cylinders more than 80 percent full)
20. What is the main danger of a large refrigerant release in a closed equipment room?
A. The refrigerant displaces oxygen and can cause suffocation. Refrigerant vapor can displace the air in a closed space, so the main hazard is oxygen deprivation. Exposure can also cause heart effects and frostbite.
From EPA, Section 608 Test Topics: Core, Safety (risks of exposure to refrigerant)
21. A refrigerant blend leaks, and the charge left in the system no longer has the original mix of components. What is this called?
C. Fractionation. Fractionation is the tendency of the components of a blend to leak at different rates, which changes the makeup of the charge that is left.
From EPA, Section 608 Test Topics: Core, Substitute Refrigerants and oils
22. Which lubricant is used with HFC refrigerants such as R-134a?
B. Ester (polyolester) oil. Substitute refrigerants are not compatible with many lubricants used with CFCs and HCFCs. Ester oils go with R-134a, while alkylbenzenes are used with HCFCs.
From EPA, Section 608 Test Topics: Core, Substitute Refrigerants and oils
23. Under the AIM Act Technology Transitions rule, when may a new residential split air conditioner using a refrigerant with a GWP of 700 or more still be installed?
A. Only if all specified components of the system were manufactured or imported before January 1, 2025. Since January 1, 2025, no one may install a new residential or light commercial AC or heat pump system using a refrigerant with a GWP of 700 or more (other than variable refrigerant flow systems, which have their own dates). The only exception is a system whose specified components were all manufactured or imported before January 1, 2025.
From 40 CFR 84.54(c)(1)
24. Starting January 1, 2028, how may a certified technician discard a used disposable cylinder that held an HFC directly to a scrap recycler?
B. After evacuating the heel to 15 inches of mercury vacuum and giving the scrap recycler a signed certification statement. From January 1, 2028, a used disposable cylinder holding an HFC heel must go to a reclaimer, a refrigerant supplier or a final processor able to remove the heel. Alternatively, a certified technician may evacuate it to 15 inches of mercury vacuum and give the final processor a signed statement saying so.
From 40 CFR 84.116(a) and (e)
Recovery levels, recovery methods, safety and disposal for factory-sealed appliances holding 5 pounds or less of refrigerant.
25. Which of these is a small appliance under 40 CFR 82.152?
C. A factory-sealed window air conditioner holding 3 pounds of refrigerant. A small appliance is fully manufactured, charged and hermetically sealed in a factory with 5 pounds or less of refrigerant, such as a household refrigerator, a window or portable room air conditioner, a PTAC heat pump, a dehumidifier or a water cooler.
From 40 CFR 82.152, definition of Small appliance
26. What is the largest refrigerant charge a small appliance can have?
B. 5 pounds. To be a small appliance, the product must be charged and hermetically sealed in the factory with 5 pounds or less of refrigerant.
From 40 CFR 82.152, definition of Small appliance
27. Which certification does a technician need to repair the sealed system of a household refrigerator?
D. Type I. Persons who maintain, service or repair small appliances must be certified as Type I (or Universal) technicians. Section 609 covers motor vehicle air conditioners.
From 40 CFR 82.161(a)(1)(i)
28. Using recovery equipment made on or after November 15, 1993, how much of the refrigerant must be recovered from a small appliance whose compressor works?
C. 90 percent. With equipment made on or after November 15, 1993, recover 90 percent of the charge when the appliance's compressor works, or 80 percent when it does not.
From 40 CFR 82.156(b)(2)
29. Using recovery equipment made on or after November 15, 1993, how much of the refrigerant must be recovered from a small appliance whose compressor does not work?
B. 80 percent. When the compressor is not working, the requirement with post-1993 equipment drops from 90 percent to 80 percent of the refrigerant in the appliance.
From 40 CFR 82.156(b)(2)
30. Using recovery equipment made before November 15, 1993, how much of the refrigerant must be recovered from a small appliance?
D. 80 percent, whether or not the compressor works. Older equipment (made before November 15, 1993) must recover 80 percent of the refrigerant in the small appliance, with no split for compressor condition.
From 40 CFR 82.156(b)(1)
31. Instead of meeting a recovery percentage, a technician may meet the small appliance requirement by evacuating the appliance to what level?
A. 4 inches of mercury vacuum. The rule lets a technician satisfy small appliance recovery by evacuating the appliance to 4 inches of mercury vacuum. The other levels belong to larger appliance types in Table 1.
From 40 CFR 82.156(b)(3)
32. Recovery equipment that needs the appliance's own compressor or internal pressure to remove the refrigerant is called what?
A. System-dependent recovery equipment. System-dependent (passive) equipment relies on components in the appliance to remove the refrigerant. Self-contained equipment has its own means, such as a compressor, and can recover without help from the appliance.
From 40 CFR 82.152, definitions of System-dependent and Self-contained recovery equipment
33. Who certifies that new recovery equipment meets EPA's standards for use with small appliances?
B. An EPA-approved equipment testing organization, such as AHRI or UL. Recovery and recycling equipment must be certified by an EPA-approved testing organization; EPA has approved AHRI and UL. Certified equipment carries a label saying so.
From EPA, Refrigerant Recovery and Recycling Equipment Certification; 40 CFR 82.158(e)
34. A small appliance using a non-exempt refrigerant must be sold with which fitting so refrigerant can be removed at service and disposal?
D. A process stub. Small appliances (except those using only exempt refrigerants) must have a process stub, a length of tubing that gives access to the refrigerant and can be resealed after service.
From 40 CFR 82.154(e)(2) and 82.152, definition of Process stub
35. A technician is using a system-dependent (passive) recovery device on a small appliance whose compressor does not run. Where should access valves be installed?
B. On both the high side and the low side. With an inoperative compressor, refrigerant will not be pumped to one side, so access valves are needed on both the high and low sides to recover it.
From EPA, Section 608 Test Topics: Type 1, Recovery Techniques
36. During passive recovery from a small appliance with an inoperative compressor, what helps release refrigerant held in the compressor oil?
A. Heating the compressor and striking it sharply. Heating the compressor and striking it sharply helps drive out refrigerant dissolved in the oil so the passive device can capture it.
From EPA, Section 608 Test Topics: Type 1, Recovery Techniques
37. A small appliance's compressor works. What should the technician do when using a system-dependent (passive) recovery device?
C. Run the appliance's compressor during recovery. A passive device depends on the appliance, so an operating compressor should be run to push refrigerant into the recovery container.
From EPA, Section 608 Test Topics: Type 1, Recovery Techniques
38. For passive recovery from a small appliance with an inoperative compressor, a vacuum pump may be used to draw refrigerant into which kind of container?
D. A non-pressurized recovery container. One accepted passive method for an inoperative compressor is a vacuum pump pulling refrigerant into a non-pressurized recovery container.
From EPA, Section 608 Test Topics: Type 1, Recovery Techniques
39. A technician put a solderless (bolt-on) piercing access fitting on a small appliance. What should be done with it when the service is finished?
B. Remove it. EPA's Type I topics call for removing solderless access fittings at the end of service rather than leaving them on the appliance.
From EPA, Section 608 Test Topics: Type 1, Recovery Techniques
40. A small appliance has been off long enough to reach room temperature. How can the technician check for noncondensables (air) in it?
A. Compare the measured pressure with the refrigerant's saturation pressure at that temperature; a higher reading points to noncondensables. Pressure and temperature together identify a refrigerant and reveal noncondensables. With liquid and vapor present at a known temperature, a pure refrigerant reads its saturation pressure; noncondensables push the reading higher.
From EPA, Section 608 Test Topics: Type 1, Recovery Techniques (pressure and temperature)
41. Which HFC was the usual substitute for CFC-12 (R-12) in small appliances?
C. R-134a. HFC-134a (R-134a) is the substitute for CFC-12 in small appliances. R-22 is an HCFC, R-502 is a blend containing R-22, and R-123 is a low-pressure HCFC used in chillers.
From EPA, Section 608 Test Topics: Type 1, Recovery Techniques
42. Under 40 CFR 82.154(a)(1), how is isobutane (R-600a) in a household refrigerator treated?
A. It is exempt from the venting prohibition and the Subpart F requirements in that use. EPA exempts isobutane (R-600a) in household refrigerators and freezers, and propane (R-290) in uses such as household refrigerators and self-contained room air conditioners, from the venting prohibition and the Subpart F requirements. Their flammability still calls for care.
From 40 CFR 82.154(a)(1)(viii) and (ix)
43. Why should refrigerant be recovered before brazing on a small appliance's tubing?
D. At high temperatures refrigerant can break down into harmful decomposition products. Refrigerant exposed to high temperatures, such as a torch flame, decomposes into hazardous products, which is a Type I safety topic.
From EPA, Section 608 Test Topics: Type 1, Safety
44. A worker at a scrap yard recovers refrigerant from household refrigerators before they are shredded. What does Section 608 require of the worker?
C. No certification, but recovery equipment that meets EPA's standards and the required recovery levels. People who dispose of small appliances do not need to be certified. The equipment they use must still meet the same performance standards as service equipment, and they must reach the small appliance recovery levels.
From 40 CFR 82.161(a)(1)(vii) and 82.155(a); EPA, Safe Disposal Requirements
45. Who is responsible for making sure refrigerant has been recovered from a household refrigerator before its final disposal?
B. The final processor, such as a scrap metal recycler or landfill operator. The final processor, the person taking the last step in disposal, must either recover the remaining refrigerant or verify with a signed statement or contract that it was recovered.
From 40 CFR 82.155(b)
46. A scrap recycler accepts a refrigerator whose refrigerant was recovered earlier by someone else. What must the signed statement include?
A. The name and address of the person who recovered the refrigerant and the date it was recovered. The signed statement must give the name and address of the person who recovered the refrigerant and the recovery date. EPA does not accept a sticker as verification.
From 40 CFR 82.155(b)(2); EPA, Safe Disposal Requirements
47. A freezer arrives at a scrap yard with no refrigerant left because of a system failure. What must the final processor obtain?
D. A signed statement that all the refrigerant leaked out before delivery and recovery is not possible. If all the refrigerant leaked out, the final processor needs a signed statement saying so. Leaked out means lost through system failure, accident or other unavoidable event, not through negligence or deliberate acts like cutting lines.
From 40 CFR 82.155(b)(2)(iii)
48. A final processor may use a contract instead of a signed statement for each appliance. Which suppliers is the contract option meant for?
C. Regular commercial suppliers. The contract option streamlines dealings with regular commercial suppliers. EPA says it is not appropriate for infrequent suppliers such as individuals and peddlers, who must provide signed statements.
From EPA, Safe Disposal Requirements: Equipment that Enters the Waste Stream with the Refrigerant Charge Intact
49. How long must the final processor of small appliances keep the signed statements or contracts it obtains?
A. 3 years. Signed statements and contracts must be kept on site, on paper or electronically, for three years.
From 40 CFR 82.155(c)
Evacuation levels, recovery and leak detection on medium-, high- and very high-pressure equipment, and the leak repair rules for large systems.
50. Under 40 CFR 82.152, how is an appliance using R-410A classified?
C. High-pressure. A high-pressure appliance uses a refrigerant with a liquid saturation pressure between 170 and 355 psia at 104°F. The rule names R-22, R-407A, R-407C, R-410A and R-502 as examples.
From 40 CFR 82.152, definition of High-pressure appliance
51. Which appliances does Type II certification cover?
A. Medium-, high- and very high-pressure appliances, except small appliances and motor vehicle air conditioners. Type II technicians maintain, service, repair or dispose of medium-, high- and very high-pressure appliances other than small appliances, MVACs and MVAC-like appliances. Small appliances are Type I and low-pressure appliances are Type III.
From 40 CFR 82.161(a)(1)(ii)
52. An R-410A system holding 15 pounds is being disposed of. Using recovery equipment made on or after November 15, 1993, to what level must it be evacuated?
B. 0 inches of mercury vacuum. Table 1 sets 0 inches of mercury vacuum for a high-pressure appliance (or isolated component) with a full charge of less than 200 pounds, whether the recovery equipment is older or newer.
From 40 CFR 82.156(a), Table 1
53. An R-22 system with a 250-pound full charge is being disposed of. Using recovery equipment made on or after November 15, 1993, to what level must it be evacuated?
C. 10 inches of mercury vacuum. For a high-pressure appliance with 200 pounds or more, Table 1 requires 10 inches of mercury vacuum with equipment made on or after November 15, 1993, and 4 inches with older equipment.
From 40 CFR 82.156(a), Table 1
54. An R-134a chiller holds 300 pounds. Before it is opened for a major repair, using recovery equipment made on or after November 15, 1993, to what level must it be evacuated?
D. 15 inches of mercury vacuum. R-134a is a medium-pressure refrigerant under 40 CFR 82.152. A medium-pressure appliance with 200 pounds or more must reach 15 inches of mercury vacuum with newer equipment (4 inches with pre-1993 equipment).
From 40 CFR 82.156(a), Table 1; 82.152, definition of Medium-pressure appliance
55. A technician will make a repair that is not major on a high-pressure system and will not evacuate the system to the atmosphere afterward. To what pressure must the system be evacuated before it is opened?
B. 0 psig. For a repair that is not major and is not followed by evacuation to the atmosphere, a medium-, high- or very high-pressure appliance need only be evacuated to no higher than 0 psig before opening. The 5 psig limit applies to oil changes.
From 40 CFR 82.156(a)(1)(i)
56. Which of these is a major repair under 40 CFR 82.152?
D. Removing the compressor. Major maintenance, service or repair means removing the compressor, condenser, evaporator or an auxiliary heat exchange coil, or uncovering more than 4 square inches of flow area for more than 15 minutes.
From 40 CFR 82.152, definition of Major maintenance, service, or repair
57. Leaks make it impossible to reach the Table 1 level on a component that must be opened. After isolating the leaking parts from the non-leaking ones, how far must the leaking component be evacuated?
B. To the lowest level reachable without substantially contaminating the refrigerant, and no higher than 0 psig. Isolate leaking from non-leaking components where possible, take non-leaking components to the Table 1 level, and evacuate leaking components to the lowest level attainable without substantially contaminating the refrigerant, never above 0 psig.
From 40 CFR 82.156(a)(2)
58. Before changing the compressor oil, to what pressure must the appliance (or the system receiver the oil is drained into) be evacuated?
C. No higher than 5 psig. Oil holds dissolved refrigerant, so for an oil change the appliance, or a system receiver the oil is drained into, must be evacuated or pressurized to no higher than 5 psig before opening.
From 40 CFR 82.156(a)(1)(iii); EPA, Service Practice Requirements: Changing Refrigerant Oil
59. System-dependent recovery equipment may not be used on appliances with a full charge of more than how many pounds, unless it is a permanently attached pump-out unit?
A. 15 pounds. System-dependent equipment is limited to appliances with a full charge of 15 pounds or less. Larger appliances need self-contained recovery equipment unless a pump-out unit is permanently attached.
From 40 CFR 82.156(e)
60. After reaching the required recovery vacuum, the technician waits a few minutes and the system pressure rises. What does this indicate?
D. Liquid refrigerant may still be in the system or in the oil. Waiting a few minutes after reaching the recovery vacuum shows whether the pressure rises. A rise indicates liquid refrigerant still in the system or in the oil, so recovery must continue.
From EPA, Section 608 Test Topics: Type 2, Recovery Techniques
61. Which step speeds up recovery from a large high-pressure system?
C. Recovering the liquid first. Recovering liquid at the start of the process speeds up recovery from a large system.
From EPA, Section 608 Test Topics: Type 2, Recovery Techniques
62. Which of these also speeds up refrigerant recovery?
B. Chilling the recovery cylinder. Chilling the recovery vessel, or heating the appliance or vessel the refrigerant is coming from, speeds up recovery.
From EPA, Section 608 Test Topics: Type 2, Recovery Techniques
63. Which is a sign of a refrigerant leak in a high-pressure system?
C. Excessive superheat. Signs of leakage in high-pressure systems include excessive superheat and, on hermetic systems, traces of oil at the leak.
From EPA, Section 608 Test Topics: Type 2, Leak Detection
64. From most to least preferred, which order of leak test gases is correct?
A. Nitrogen alone; nitrogen with a trace of R-22; pure refrigerant. Nitrogen alone is best. Nitrogen with a trace of HCFC-22 is next, and both are better than pressurizing with pure refrigerant. A system should be leak tested before it is charged or recharged.
From EPA, Section 608 Test Topics: Type 2, Leak Detection
65. A gauge on an R-22 system reads 120 psig. What is the absolute pressure?
B. 134.7 psia. Absolute pressure equals gauge pressure plus atmospheric pressure, 14.7 psi at sea level: 120 + 14.7 = 134.7 psia. Pressure-temperature charts may be in either unit, so convert before comparing.
From EPA, Section 608 Test Topics: Type 2, Refrigeration (add 14.7 to convert psig to psia)
66. Which practice should be avoided while a high-pressure system with a hermetic compressor is under deep vacuum?
A. Energizing the hermetic compressor. A hermetic compressor should not be energized while the system is under vacuum. EPA lists this as a Type II safety point.
From EPA, Section 608 Test Topics: Type 2, Safety
67. A customer wants an R-22 central air conditioner converted to a propane-based refrigerant sold as R-22a. What is correct?
D. Hydrocarbons such as R-22a are not approved for use in existing air-conditioning systems. Hydrocarbons are not approved for retrofits. Products named R-22a are highly flammable, have never been submitted to EPA for review, and are not approved for existing air conditioners; EPA has taken enforcement action against their use.
From EPA, Section 608 Test Topics: Type 2, Refrigeration; EPA, Resources for Technicians: Flammable Refrigerants and Technician Safety
68. An office building's R-22 comfort cooling system has a full charge of 120 pounds. Above what annual leak rate must its leaks be repaired?
A. 10 percent. For appliances with 50 or more pounds of ozone-depleting refrigerant, the trigger is 10 percent for comfort cooling, 20 percent for commercial refrigeration and 30 percent for industrial process refrigeration. The 2016 rule lowered comfort cooling from 15 percent to 10.
From 40 CFR 82.157(c)(2); EPA, Regulatory Updates (2016 Rule Summary)
69. A supermarket's R-22 refrigeration rack has a full charge of 300 pounds. Above what annual leak rate must it be repaired?
B. 20 percent. Retail food and cold storage systems are commercial refrigeration, with a 20 percent trigger. 30 percent is for industrial process refrigeration, and 35 percent was the old limit before the 2016 rule.
From 40 CFR 82.157(c)(2)(i); 82.152, definition of Commercial refrigeration
70. An R-22 commercial refrigeration system with a 200-pound full charge needs 20 pounds added. The last addition was 60 days ago. Using the annualizing method, what is the leak rate?
C. 60.8 percent. Annualizing method: (pounds added / full charge) / (days since last addition / 365) x 100 = (20 / 200) / (60 / 365) x 100 = 0.10 / 0.1644 x 100 = 60.8 percent. That is above the 20 percent trigger, so the leaks must be repaired.
From 40 CFR 82.152, definition of Leak rate (Annualizing Method)
71. Refrigerant is added to a 120-pound R-22 comfort cooling system that is leaking above its trigger rate, and no industrial process shutdown is involved. Within how many days must the leaks be found and repaired?
B. 30 days. Leaks must be identified and repaired within 30 days of the refrigerant addition, or 120 days when an industrial process shutdown is needed. A certified technician must do the leak inspection.
From 40 CFR 82.157(d)
72. After a successful initial verification test on a leak repair, within how many days must the follow-up verification test be done?
D. 10 days. The follow-up verification test must be done within 10 days of the successful initial verification test, or within 10 days of the appliance reaching normal operating conditions if it was evacuated for the repair.
From 40 CFR 82.157(e)(2)
73. An owner must report to EPA by March 1 when an appliance with 50 or more pounds of ozone-depleting refrigerant leaks how much of its full charge in a calendar year?
A. 125 percent or more. Appliances that leak 125 percent or more of their full charge in a calendar year are chronic leakers. The owner must report the efforts to find and repair the leaks to EPA by March 1 of the next year.
From 40 CFR 82.157(j)
74. As of January 1, 2026, which of these appliances falls under the federal HFC leak repair rule in 40 CFR 84.106?
D. A 40-pound R-134a commercial refrigeration system. Since January 1, 2026, leak repair applies to appliances with 15 or more pounds of an HFC (or a substitute with a GWP above 53), with the same 10, 20 and 30 percent triggers. Residential and light commercial air conditioning and heat pumps are excluded. Under 40 CFR 82.157 alone, the federal leak repair rule covered only ozone-depleting refrigerants in 50-pound or larger appliances.
From 40 CFR 84.106(a) and (c)(2)
Evacuation, pressurizing, leak testing, recovery, recharging and leak repair on low-pressure chillers such as R-11 and R-123 machines.
75. Which refrigerant makes an appliance a low-pressure appliance under 40 CFR 82.152?
C. R-123. The rule names R-11, R-123, R-113 and R-245fa as low-pressure refrigerants. R-134a is medium-pressure, and R-22 and R-410A are high-pressure.
From 40 CFR 82.152, definition of Low-pressure appliance
76. A low-pressure appliance uses a refrigerant with a liquid saturation pressure in what range at 104°F?
A. Below 45 psia. Low-pressure means below 45 psia at 104°F. 45 to 170 psia is medium-pressure, 170 to 355 psia is high-pressure, and above 355 psia (or a critical temperature below 104°F) is very high-pressure.
From 40 CFR 82.152, pressure class definitions
77. Which certification does a technician need to service an R-123 centrifugal chiller?
D. Type III. Persons who maintain, service, repair or dispose of low-pressure appliances must be certified as Type III (or Universal) technicians.
From 40 CFR 82.161(a)(1)(iii)
78. An R-11 chiller is being disposed of. Using recovery equipment made on or after November 15, 1993, to what level must it be evacuated?
C. 25 mm Hg absolute. Table 1 requires 25 mm Hg absolute for every low-pressure appliance, whatever its charge size.
From 40 CFR 82.156(a), Table 1
79. With recovery equipment made before November 15, 1993, what evacuation level applies to a low-pressure appliance?
D. 25 mm Hg absolute, the same as with newer equipment. Unlike the high- and medium-pressure rows of Table 1, the low-pressure level does not change with the age of the recovery equipment: it is 25 mm Hg absolute either way.
From 40 CFR 82.156(a), Table 1
80. For a repair that is not major and is not followed by evacuation to the atmosphere, what must be done to a low-pressure appliance before it is opened?
B. Pressurize it to no higher than 0 psig. A low-pressure appliance is pressurized (not evacuated) to no higher than 0 psig before opening for a non-major repair, and openings must be covered when isolation is not possible.
From 40 CFR 82.156(a)(1)(ii)
81. Which is an allowed way to raise an R-123 chiller to 0 psig for a non-major repair?
C. Controlled hot water. Controlled hot water or a built-in heating/pressurization device such as Prevac may be used. Methods that need purging afterward, such as nitrogen, may not be used except on R-113 appliances.
From EPA, Service Practice Requirements: Repairs that are Not Major; EPA, Section 608 Test Topics: Type 3, Recovery Requirements
82. An R-113 appliance (its refrigerant boils above 85°F at 29.9 inches of mercury) needs a non-major repair. How may it be brought up to atmospheric pressure?
B. With heat as far as possible, then nitrogen for the rest of the way to atmospheric. For refrigerants boiling above 85°F at standard atmospheric pressure, heat must be used to raise the pressure as much as possible, and nitrogen may then take it from that level to atmospheric. For refrigerants boiling at or below 85°F, methods that need later purging, like nitrogen, are not allowed.
From 40 CFR 82.156(a)(1)(ii)
83. After a low-pressure chiller reaches the required recovery vacuum, the technician waits a few minutes and the pressure rises. What does this mean?
A. Liquid refrigerant may still be in the system or in the oil. A pressure rise after reaching the recovery vacuum indicates liquid refrigerant still in the system or in the oil, so recovery must continue.
From EPA, Section 608 Test Topics: Type 3, Recovery Requirements
84. All the liquid R-123 has been removed from a chiller. What remains to be done?
B. Recover the remaining vapor too. Liquid is recovered first because it speeds the job, but the vapor must be recovered as well. Venting it would violate the venting prohibition.
From EPA, Section 608 Test Topics: Type 3, Recovery Techniques
85. Before oil is drained from a low-pressure chiller, to what temperature should it be heated to reduce the refrigerant released?
C. 130°F. Heating the oil to 130°F before removing it minimizes the refrigerant released with the oil.
From EPA, Section 608 Test Topics: Type 3, Recovery Techniques
86. Why must the water in a chiller's tubes be circulated or drained while the refrigerant is being evacuated?
A. To keep the water from freezing. Circulating or removing the water from the chiller during refrigerant evacuation keeps it from freezing in the tubes.
From EPA, Section 608 Test Topics: Type 3, Recovery Techniques
87. When recharging an evacuated low-pressure chiller, what should be introduced first?
B. Refrigerant vapor. Introduce vapor before liquid. This prevents the water in the tubes from freezing.
From EPA, Section 608 Test Topics: Type 3, Recharging Techniques
88. Through which point should a centrifugal chiller be charged?
D. The evaporator charging valve. Centrifugal chillers are charged through the evaporator charging valve.
From EPA, Section 608 Test Topics: Type 3, Recharging Techniques
89. When pressurizing a low-pressure chiller to look for leaks, which method is preferred over nitrogen?
A. The hot water method or a built-in heating/pressurization device such as Prevac. For low-pressure systems the preferred leak test pressurization is the hot water method or a built-in heating/pressurization device such as Prevac, with nitrogen next.
From EPA, Section 608 Test Topics: Type 3, Leak Detection
90. Which sign points to a leak into a low-pressure chiller?
D. Excessive purging. EPA lists excessive purging as a sign of leakage into a low-pressure system: the purge unit runs more because of what has leaked in.
From EPA, Section 608 Test Topics: Type 3, Leak Detection
91. Under ASHRAE Standard 15, what does an equipment room with an R-123 chiller need?
A. A refrigerant sensor. ASHRAE Standard 15 requires a refrigerant sensor in the equipment room for R-123, as listed in EPA's Type III safety topics.
From EPA, Section 608 Test Topics: Type 3, Safety
92. An R-123 chiller with a 600-pound full charge cools a pharmaceutical process. Above what annual leak rate must it be repaired?
C. 30 percent. Equipment directly linked to chemical, pharmaceutical, petrochemical or manufacturing processes is industrial process refrigeration, with a 30 percent trigger. 35 percent was the limit before the 2016 rule.
From 40 CFR 82.157(c)(2)(ii); 82.152, definition of Industrial process refrigeration
93. An R-11 chiller with an 800-pound full charge cools an office building. Above what annual leak rate must it be repaired?
D. 10 percent. Comfort cooling appliances with 50 or more pounds of ozone-depleting refrigerant must be repaired above a 10 percent leak rate. The trigger was 15 percent before the 2016 rule.
From 40 CFR 82.157(c)(2)(iii); EPA, Leak Repair Requirements: Trigger Rates
94. An industrial process refrigeration chiller has to be shut down to repair its leaks. How long is the repair period?
B. 120 days. The normal repair period is 30 days. When an industrial process shutdown is required, it is 120 days.
From 40 CFR 82.157(d)
95. After an R-123 comfort cooling chiller exceeds its leak rate, how often must leak inspections be done if it has no automatic leak detection system?
C. Once per calendar year, until it has not leaked above the rate for one year. Comfort cooling appliances are inspected once per calendar year until the leak rate calculations show no exceedance for a year. Commercial and industrial process systems of 500 pounds or more are inspected every three months.
From 40 CFR 82.157(g)(1)
96. An automatic leak detection system that senses refrigerant in the air can take the place of periodic leak inspections if it can do what?
B. Detect 10 ppm and alarm at 100 ppm. The system must accurately detect 10 parts per million of the refrigerant's vapor, alert the owner at 100 parts per million, watch components inside an enclosed building, and be audited or calibrated every year.
From 40 CFR 82.157(g)(4)
97. The owner of a leaking R-11 chiller decides to retire it instead of repairing it. When must the retirement plan be written, and when must the work be finished?
A. Within 30 days; within one year of the plan's date. A retrofit or retirement plan must be created within 30 days, and the work must be finished within one year of the plan's date unless EPA grants more time.
From 40 CFR 82.157(h)(1) and (h)(5)
98. An owner is retiring a leaking chiller and the replacement uses a refrigerant that is exempt under 40 CFR 82.154(a). How long is the owner automatically allowed to retire the old appliance?
D. 18 months. Owners of any appliance type are automatically allowed 18 months to retire an appliance when the replacement uses an exempt substitute refrigerant, instead of the usual one year.
From 40 CFR 82.157(i)(1)
99. A 400-pound comfort cooling chiller uses R-245fa, a low-pressure HFC. Since January 1, 2026, which federal leak repair rule applies to it?
B. 40 CFR 84.106, with a 10 percent trigger leak rate. The 2020 rule took HFC appliances out of the 40 CFR 82.157 leak repair rule. The 2024 AIM Act rule brought appliances with 15 or more pounds of an HFC back under leak repair from January 1, 2026, in 40 CFR 84.106, with a 10 percent trigger for comfort cooling.
From 40 CFR 84.106(a) and (c)(2)(iii); EPA, Regulatory Updates (2020 Rule Summary)
Offered to people preparing for EPA 608. We may earn a share of what you pay if you buy through these links. It never changes your price, and the sellers have no say in the jobs we list.
More free practice tests: Journeyman Electrician Practice Test · Journeyman Plumber Practice Test · OSHA 10 Practice Test · OSHA 30 Practice Test · Electrical Aptitude Test Practice · UA Plumbers and Pipefitters Aptitude Test Practice · EEI CAST Test Practice · Contractor Business and Law Practice Test · CSLB Law and Business Practice Test · Florida Business and Finance Exam Practice Test · Arizona Statutes and Rules Exam Practice Test · Nevada Business and Law Exam Practice Test · Utah Business and Law Exam Practice Test · Louisiana Business and Law Exam Practice Test · South Carolina Business and Law Exam Practice Test · North Carolina General Contractor Exam Practice Test · Oregon CCB Test Practice Test · New Mexico Business and Law Exam Practice Test · Alabama Business and Law Exam Practice Test · Hawaii Business and Law Exam Practice Test · OSHA 10 General Industry Practice Test · Forklift Practice Test
No. The bodies that give the real exam keep its questions to themselves. Each question here is written for the rules or skills the exam tests, and its explanation shows the working or names the section of the regulation or code it comes from, so you learn the rule rather than one answer.
Yes. All 99 questions and their explanations are free, with no sign-up. Your answers stay in your browser.
Checked against the rules in force on 2026-11-26. Rules and exam formats change: check the current rule and your exam provider's own information before the exam.